Plain bearing wiki

What does the pv value mean?

PV value

In these equations:

  • K1. K2 = Constant for heat dissipation (K1 = 0.5, K2 = 0.042)
  • Øs = Bearing wall thickness, mm
  • b1 = Bearing length [mm] [mm]
  • μ = Coefficient of friction
  • λs = Thermal conductivity of the shaft
  • λk = Thermal conductivity of the bearing
  • ΔT = (Ta - Tu)
  • Tu = Ambient temperature
  • Ta = Max. Application temperature
pv value graph

Correction Factor

  • Dry operation = correction factor 1
  • During installation = correction factor 1.3
  • Continuous, grease = correction factor 2
  • Continuous, water = correction factor 4
  • Continuous, oil = correction factor 5